Tempered Glass Requirements In Doors

According to the international building code which has been adopted by the state of texas any glass in a window that is within 2 feet of a door and within 53 of the finished floor surface.
Tempered glass requirements in doors. Nearby doors change the rules about tempered glass because the swing of a door or the motions of a person going through it can create a situation where a regular window might break. In addition any glass located adjacent to a door within a 24 inch arc of the door must be constructed from safety glass if the bottom edge of the glass is less than 60 inches above the walking. When is safety tempered glass required by code for glass near a door. There are also four exception allowed as noted below in the citation from the residential edition of the florida building code fbc and the international residential code irc is similar.
Any windows in a door must have tempered glass no matter the height unless it is too small for a 3 inch ball to pass through the window. Above floor or standing surface 1. Arc of the door in closed position 60 in. Saturday october 5 2019.
Any glass alongside a stairway landing or ramp. Additionally it is required to temper any glass located within 24 of a door if the bottom edge is less than five feet above the floor. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process. Glass perpendicular to door on latch side 4.
Openings that would prevent passage of a 3 in. Anything within 2 of a door on the hinge side. Tempered glass in doors according to the international residential code you must temper all glass and panels in swinging sliding operable fixed and bifold doors regardless of the panel s size. When protected by intervening barrier 3.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. A glass panel so small that a 3 ball cannot go through it or if the glass is categorized as decorative. Also any fixed window with over 9. All doors manufactured since 1974 have tempered glass.
1 glazing in doors 1. Decorative glass 2 sidelites where any part of glass within 24 in. All standard french doors would not pass the 3 ball test and must be safety tempered. Doors are considered a hazardous location for the purpose of where safety tempered glass is required in a home and all door glazing is required to be safety tempered with only two exceptions.